توضیحات
Power Quality Issues: Current Harmonics provides solutions for the mitigation of power quality problems related to harmonics. Focusing on active power filters (APFs) due to their excellent harmonic and reactive power compensation in two-wire (single phase), three-wire (three-phase without neutral), and four-wire (three-phase with neutral) AC power networks with nonlinear loads, the text: Introduces the APF technology, describing various APF configurations and offering guidelines for the selection of APFs for specific application considerations; compares shunt active filter (SHAF) control strategies for extracting three-phase reference currents, evaluating their performance under a number of source voltage conditions using a proportional-integral (PI) controller; presents PI controller-based SHAF instantaneous active and reactive power (p-q) and instantaneous active and reactive current (Id-Iq) control strategies, supplying detailed MATLAB/Simulink simulation results; proposes SHAF control strategies using type 1 and type 2 fuzzy logic controllers (FLCs) with different fuzzy membership functions (MFs), analyzing their harmonic mitigation and DC link voltage regulation; verifies the proposed type 2 FLC-based SHAF control strategies with trapezoidal, triangular, and Gaussian fuzzy MFs using RT-LAB, a real-time digital simulation software from OPAL-RT Technologies. Read more…
Abstract: Power Quality Issues: Current Harmonics provides solutions for the mitigation of power quality problems related to harmonics. Focusing on active power filters (APFs) due to their excellent harmonic and reactive power compensation in two-wire (single phase), three-wire (three-phase without neutral), and four-wire (three-phase with neutral) AC power networks with nonlinear loads, the text: Introduces the APF technology, describing various APF configurations and offering guidelines for the selection of APFs for specific application considerations; compares shunt active filter (SHAF) control strategies for extracting three-phase reference currents, evaluating their performance under a number of source voltage conditions using a proportional-integral (PI) controller; presents PI controller-based SHAF instantaneous active and reactive power (p-q) and instantaneous active and reactive current (Id-Iq) control strategies, supplying detailed MATLAB/Simulink simulation results; proposes SHAF control strategies using type 1 and type 2 fuzzy logic controllers (FLCs) with different fuzzy membership functions (MFs), analyzing their harmonic mitigation and DC link voltage regulation; verifies the proposed type 2 FLC-based SHAF control strategies with trapezoidal, triangular, and Gaussian fuzzy MFs using RT-LAB, a real-time digital simulation software from OPAL-RT Technologies
مسائل کیفیت توان: Current Harmonics راه حل هایی را برای کاهش مشکلات کیفیت توان مربوط به هارمونیک ها ارائه می دهد. تمرکز بر فیلترهای توان اکتیو (APF) به دلیل جبران هارمونیک و توان راکتیو عالی در دو سیم (تک فاز)، سه سیم (سه فاز بدون نول) و چهار سیم (سه فاز با خنثی) AC شبکههای با بارهای غیرخطی، متن: فناوری APF را معرفی میکند، پیکربندیهای مختلف APF را توصیف میکند و دستورالعملهایی برای انتخاب APFها برای ملاحظات کاربردی خاص ارائه میدهد. استراتژی های کنترل فیلتر فعال شنت (SHAF) را برای استخراج جریان های مرجع سه فاز، ارزیابی عملکرد آنها تحت تعدادی از شرایط ولتاژ منبع با استفاده از یک کنترل کننده انتگرال متناسب (PI) مقایسه می کند. استراتژی های کنترل لحظه ای توان اکتیو و راکتیو آنی SHAF و جریان اکتیو و راکتیو آنی (Id-Iq) مبتنی بر کنترل کننده PI را ارائه می دهد و نتایج شبیه سازی MATLAB/Simulink دقیق را ارائه می دهد. استراتژیهای کنترل SHAF را با استفاده از کنترلکنندههای منطق فازی نوع 1 و نوع 2 (FLCs) با توابع عضویت فازی مختلف (MFs) پیشنهاد میکند، کاهش هارمونیک آنها و تنظیم ولتاژ پیوند DC را تحلیل میکند. استراتژیهای کنترل SHAF مبتنی بر FLC نوع 2 پیشنهادی را با MFهای فازی ذوزنقهای، مثلثی و گاوسی با استفاده از RT-LAB، یک نرمافزار شبیهسازی دیجیتال بلادرنگ از OPAL-RT Technologies تأیید میکند. ادامه مطلب…
نقد و بررسیها
هنوز بررسیای ثبت نشده است.